This paper briefly describes the composition principle of the electrical fire monitoring system, and analyzes the design basis and related specifications of the electrical fire monitoring system in the application. Finally, an example of the in vitro diagnostic automatic coagulation analysis industrialization project by Ankerui residual current electric fire monitoring system is introduced, and the realization of the function of the electric fire monitoring system and its significance are expounded.
Yang Junjun An Kerui Electric Co., Ltd. Shanghai Jiading



0 Overview

Shanghai Sun Biotechnology Co., Ltd. is located in Xinzhuang Industrial Zone, Minhang District, Shanghai. It was established in 1996 and is a high-tech enterprise in Shanghai.

Shanghai Sun Biotechnology Co., Ltd. is one of the first production enterprises to obtain the Medical Device Manufacturing Enterprise License issued by Shanghai Food and Drug Administration. It has the first production plant covering more than 10,000 square meters in compliance with GMP standards and passed ISO13485: 2003. And ISO9001: 2000 dual international quality system certification, and passed the EU CE system certification for export license.

More than 80% of the company's employees are college graduates or above, and there is a research and development team composed of senior talents with master's degree or above. It has strong research and development and scientific research achievements, and is leading domestically in the research and development and production of diagnostic reagents. Status, the company's mainstream products coagulation four (PT, APTT, TT, FIB) the actual use of hospitals accounted for 65% of all domestic brands. It is the largest manufacturer of thrombus hemostasis reagents in China. Its products are distributed in more than 5,000 hospitals, pharmaceutical factories, colleges and universities in 31 provinces and cities nationwide, and exported to India, the Middle East, Europe and other countries.

The company's electrical fire monitoring system Acrel-6000 is Shanghai Sun Biotechnology Co., Ltd. in Huaning Road, Xinzhuang Industrial Zone, Minhang District, Shanghai (the south side of Yuxing Road, the west side of Huaning Road, the north side of Hengsha River, and the east side of Shagang River). The division provides electrical safety.



1 reference standard

In recent years, in order to increase the intensity of electrical fire monitoring and prevention, the state has successively formulated or revised a number of relevant standards and regulations to strengthen the prevention of electrical fires. There are:

(1). It is GB50045-95 (2005 edition) "Code for Fire Protection Design of High-rise Civil Buildings", which stipulates in Article 9.5.1 that it is necessary to install a leakage fire alarm system in places with high fire risk and dense personnel in high-rise buildings.

(2). It is GB50016-2006 "Code for Fire Protection of Building Design", which is stipulated in Article 11.2.7: The following places should be equipped with residual current action electrical fire monitoring system. These venues include various types of theaters, galleries, warehouses, residential communities, hospitals, shops, schools, and more.

(3). The relevant provisions of the national standard "Building electrical fire prevention requirements and testing methods" also clearly require that "the residual current action protector that automatically cuts off the power or alarm should be set at the power incoming end".

(4). The products of the electrical fire monitoring system shall meet: GB14287.1-2005 "Electrical Fire Monitoring Equipment", GB14287.2-2005 "Residual Current Electric Fire Monitoring Detector", GB14287.3-2005 "Measurement Temperature Electric Fire Monitoring and Detection" 》

(5). The installation and operation of the electrical fire monitoring system shall meet the requirements of GB13955-2005 "Installation and operation of residual current action protection device"

(6). The power supply of the electrical fire monitoring system shall meet the requirements of GB50052 "Design Specifications for Power Supply and Distribution Systems"

(7). The design of the electrical fire monitoring system shall meet the requirements of the Design Method of Electrical Fire Monitoring System (Interim Provisions)



2 system components

According to the national standard GB14287-2005 "Electrical fire monitoring system" and related specifications "Electrical fire monitoring system design method" (interim regulations), the basic components of the electrical fire monitoring system should include: electrical fire monitoring equipment, residual current electrical fire It consists of three basic product categories: monitoring detectors and temperature-measuring electrical fire monitoring detectors.

The residual current type electrical fire monitoring system adopts a layered distributed structure, which is composed of a station control layer, a network communication layer and a field device layer. Each electrical fire monitoring detector accesses the communication server through the shielded twisted pair RS485 interface, adopts the MODBUS communication protocol bus type connection, and then enters the industrial switch through the Category 5 TCP/TP protocol, and then reaches the monitoring host through the optical cable.

System networking structure

1) Station management

The management of the station control management system for the electrical fire monitoring system is the direct window of human-computer interaction and the uppermost part of the system. Mainly composed of system software and necessary hardware equipment, such as touch screen, UPS power supply and so on. The monitoring system software calculates, analyzes, and processes various types of data information on the site, and responds to the on-site transportation situation by means of graphics, digital display, sound, and indicator lights.

Monitoring host: used for data collection, processing, and data forwarding. Provides data interfaces for system management, maintenance, and analysis within and outside the system.

UPS: Ensure the normal power supply of the computer monitoring system, and ensure the normal operation of the station management management equipment when the whole system has power supply problems.

The background monitoring device is set in the control center. Since the monitoring point is less than 48, Acrel-6000/B is selected.
2) Network communication layer

Communication medium: The system mainly adopts shielded twisted pair cable, realizes real-time communication between field device and host computer by RS485 interface and MODBUS communication protocol.

3) Field device layer

The field device layer is a data acquisition terminal, mainly for the ARCM200BL residual electrical fire monitoring detector.

The ARCM200BL residual current type electrical fire monitoring detector is designed for TT and TN systems below 0.4kV. It monitors and manages fire risk parameters such as residual current, wire temperature, over current and over voltage in the distribution circuit. Thereby preventing the occurrence of electrical fires. The product adopts advanced microcontroller technology, with high integration, small size, convenient installation, intelligent, digital and networked. It is an ideal choice for building electrical fire prevention monitoring and system insulation aging prediction. The product complies with the standard requirements of GB14287.2-2005 "Electrical Fire Monitoring System Part 2: Residual Current Electrical Fire Monitoring Detector".

The on-site monitoring equipment is installed in the low-voltage power distribution cabinet of the substation. Since the monitoring circuit in the single cabinet is only one way, the ARCM200BL-J1 is selected.

The distributed I/O controller connected to the fieldbus constitutes a data collection terminal and uploads the collected data to the data center. The measurement detector is responsible for the most basic data acquisition tasks, and the monitored data must be transmitted to the monitoring host in complete, accurate and real-time. It is convenient for the operating personnel to monitor the running status of the field equipment, fault alarms, etc., to effectively prevent fire accidents.



China Hardware Business Network

3 system characteristics and working principle

The characteristic of the electrical fire monitoring system is that the residual current electrical monitoring is an advanced pre-alarm system. Unlike the traditional automatic fire alarm system, the early warning of the electrical fire monitoring system is to avoid losses, while the traditional automatic fire alarm system is to reduce losses. Therefore, this means that whether it is a new or rebuilt project, especially the unit that has installed the automatic fire alarm system, the root cause of the electrical fire monitoring system still needs to be installed.

The electrical fire monitoring system measures two physical quantities of residual current and temperature.

The residual current measurement is based on Kirchhoff's current law: at the same time, the sum of the current vectors flowing into and out of a node in the circuit is zero. Taking the TN-S system as an example, A/B/C/N is simultaneously passed through the residual current transformer. When there is no leakage in the system, the current vector sum of the residual current transformer flowing into and out is zero. At this time, the residual current The secondary current induced by the transformer is also 0; when a relatively large earth leakage occurs, the current vector sum of the current transformer flowing into and out of the residual current is no longer zero, and its magnitude is equal to the current flowing from the earth, that is, the leakage current. The leakage signal is transmitted to the electrical fire detector through the secondary wiring of the residual current transformer, and is sent to the CPU after operation amplification, A/D conversion, and after a series of algorithms, the amplitude of the change is analyzed and judged, and The alarm set value is compared. If the set value is exceeded, an audible and visual alarm signal is sent and sent to the background electrical fire monitoring device.

The temperature measurement uses a temperature sensor, which is generally measured using a Pt100 sensor. This type of temperature sensor is stable in temperature measurement and has a wide measuring range. It is suitable for monitoring cable temperature and ambient temperature in the field. When the temperature changes, the resistance value of Pt100 changes in the same proportion. The resistance signal is transmitted to the electrical fire detector. After a series of signal conversion and calculation, the final result is compared with the temperature alarm setting. If the value exceeds the fixed value. An audible and visual alarm signal is sent and sent to the background electrical fire monitoring device.



4 System parameter configuration

4.1 Alarm value setting range

According to the national standard GB14287.2-2005, the alarm value of the residual current type electrical fire monitoring detector is set between 20~1000mA. According to this requirement, the residual current action value at the power supply main line is generally set to 400~800mA, and the residual current action value on the power branch line is set to 100~400mA. Generally, the residual current type electrical fire monitoring detection is set at the actual site. The alarm value of the device shall not be less than 2 times the maximum value of the leakage current during normal operation of the protected electrical circuit and equipment, and not more than 1000 mA. The alarm setting value of the electrical fire detector should take into account the normal leakage current of the power distribution system and the electrical equipment.

4.2 Refer to the cable temperature rise alarm setting reference, according to the "Power Cable Design Specification" for the cable temperature requirements

(1) High temperature places above 60 °C should be selected according to the requirements of high temperature, duration and insulation type. Heat-resistant PVC, XLPE or Ethylene-propylene rubber insulation and other heat-resistant cables should be used. Insulated cable. It is not advisable to use ordinary PVC insulated cables in high temperature places.

(2) The ambient temperature of the cable's continuous allowable current carrying capacity shall be determined according to the multi-year average of the meteorological temperature of the area of ​​use and shall comply with the regulations. When the indoor cable trench is laid, the ambient temperature is the average daily maximum temperature of the hottest month of the site plus 5 °C.

(3) The temperature rise of the cable is related to the laying and heat dissipation conditions.



5 System Introduction China Hardware Business Network

The Acrel-6000 electrical fire monitoring system is an industrial grade that is independently developed by the company to receive field devices such as residual current electrical fire detectors to achieve alarm, monitoring, control, and management of protected electrical circuits. Hardware/software system. The system is applied to the fire control center of large shopping malls, living quarters, production bases, office buildings, shopping malls and other areas, and telemetry, remote adjustment, remote control and remote signaling of detectors scattered in the building are convenient for monitoring and management. The system uses a standard Modbus field bus to connect detectors with communication functions. When the detected parameter in the field protection circuit exceeds the alarm set value, it can send out alarm signals and control signals, can indicate the alarm part and save the alarm. information.



The main technical parameters

(1). Power supply:

1 rated working voltage AC220V (-15% ~ +10%)

2 Backup power supply: When the main power supply is under voltage or power failure, maintain the monitoring equipment working time ≥ 4 hours

(2). Work system:

24-hour work schedule

(3). Communication method:

RS485 bus communication, Modbus-RTU communication protocol, transmission distance 1km, can extend communication transmission distance through repeater

(4). Monitoring capacity:

1 Monitoring equipment can monitor up to 200 monitoring units (detectors)

2 can be connected with ARCM series monitoring detector

(5). Monitoring alarm items:

1 Residual current fault (leakage): fault unit attribute (part, type)

2 Temperature alarm (over temperature): Fault unit attribute (part, type)

3 Current fault (overcurrent): Fault unit attribute (part, type)

Monitoring alarm response time: ≤30s

Monitoring alarm sound pressure level (A weighting): ≥70dB/1m

Monitoring alarm light display: red LED indicator, red light alarm signal should be maintained until manual reset

Monitoring alarm sound signal: can be manually eliminated, can be started again when there is alarm signal input again

(6). Fault alarm item:

1 The communication cable between the monitoring device and the detector is open or shorted.

2 Monitoring equipment main power supply undervoltage or power failure

3 The cable between the charger that charges the battery and the battery is broken or shorted.

Fault alarm response time: ≤100s

Monitoring alarm sound pressure level (A weighting): ≥70dB/1m

Monitoring alarm light display: yellow LED indicator, yellow light alarm signal should be kept until troubleshooting

Fault alarm sound signal: can be manually eliminated, can be started again when there is an alarm signal input again

The normal operation of the non-faulty loop is not affected during the fault

(7). Control output:

Alarm control output: 1 set of normally open passive contacts, capacity: AC250V 3A or DC30V 3A

(8). Self-test items:

1 Indicator check: alarm, fault, operation, main power, standby power indicator

2 display check

3 audio device inspection

Self-test time ≤60s

(9). Event record:

1 Record content: record type, time of occurrence, detector number, area, fault description, can store no less than 20,000 records

2 record query: query according to the date, type and other conditions of the record

(10). Operational rating:

1 Daily duty class: real-time status monitoring, event record query

2 Monitoring operation level: real-time status monitoring, event record query, detector remote reset, device self-test

3 System management level: real-time status monitoring, event record query, detector remote reset, device self-test, monitoring device system parameter query, monitoring device module detection, operator addition and deletion

(11). Environmental conditions for use:

1 Workplace: Fire control room, manned substation (distribution room), wall on room where someone is on duty

2 Working environment temperature: 0 ° C ~ 40 ° C

3 Working environment relative humidity: 5% ~ 95% RH

4 Altitude: ≤2500m



basic skills

(1). Monitoring alarm function:

The monitoring equipment can receive the leakage and temperature information of multiple detectors, and emit an audible and visual alarm signal when the alarm occurs. At the same time, the red “alarm” indicator on the device lights up, the display indicates the alarm location and alarm type, and the alarm time is recorded. The sound and light alarm is always maintained. Until the display is reset by pressing the display "Reset" button. The audible alarm signal can also be manually removed using the display "Muffler" button.

(2). Fault alarm function:

Communication failure alarm: When a communication failure occurs between the monitoring device and any of the connected detectors, the corresponding detector in the monitoring screen displays a fault indication, and the yellow “fault” indicator on the device lights up, and a fault alarm sound is emitted. .

Power failure alarm: When the main power or backup power fails, the monitoring device also emits an audible and visual alarm signal and displays the fault information. Go to the corresponding interface to view detailed information and release the alarm sound.

(3). Self-test function:

Check that all status indicators, display, and speakers in the device are normal.

(4). Alarm record storage query function:

When leakage, over-temperature alarm or communication or power failure occurs, the alarm part, fault information, alarm time and other information are stored in the database. When the alarm is cancelled or the fault is eliminated, the same is recorded. Historical data provides a variety of convenient and fast ways to query.

(5). Power function:

When the main power supply has a power failure, undervoltage, etc., the monitoring equipment can automatically switch to the standby power supply. When the main power supply returns to normal power supply, it automatically switches back to the main power supply, ensuring continuous and smooth operation of the monitoring equipment during the switching process.

(6). Detector control function:

Remote monitoring of all detectors connected to the unit is possible through monitoring software operation.

(7). Authority control function:

In order to ensure the safe operation of the monitoring system, the monitoring device software operation authority is divided into three levels, and different levels of operators have different operation rights.

Since its operation, the system has operated well and played an important role in preventing electrical fires. It has gained recognition and trust from customers for products and companies.



references

[1]. Ren Zhicheng Zhou Zhong. Principles and Application Guidelines of Power Electrical Measurement Digital Instrumentation [M]. Beijing. China Electric Power Press. 2007. 4

[2]. Zhou Zhong. Application of power meter in electric energy metering of large public buildings [J]. Modern Building Electric 2010. 6



About the author: Yang Junjun, female, undergraduate. Position: Now working for Ankerui Electric Co., Ltd., contact number, mobile phone, QQ
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn

Other Door Accessories

Sectional Door Accessories: motor 220V-380V, control box, spring break device, cable break device , aluminum alloy rope pulley, enhanced shaft bracket, air bag system, duplex enhanced guide wheel bracket.

Detail introduction for above main accessories

1.Motor and controller:

The garage door operator is designed for residential overhead sectional and tilt doors.

The operator memorizes the limit positions and unique braking system that slows the unit down at the end of its travel.

Rolling code remote control with max. 20 pcs hand transmitters.

The operator is equipped with a manual release lever which allows manual operation of the door in case of power failure.

The controller has a security LOCK function which prevents operation of the door from transmitter.

2.spring break device:

Sectional doors are hinged and they bend in the tracks as the door opens and closes. Many of these doors are counterbalanced with extension springs, also designated "stretch springs," and they have seven characteristics. The length is the measurement of all the coils pressed together. This, along with the inside diameter of the coils and wire size - the thickness of the wire from which the springs are made - determine the stretch, the distance the spring is extended - normally half the door height, and pull, the force the spring pulls when stretched its normal length. The type of ends determine how the ends of the spring are mounted. The initial tension is the percentage of pull needed to separate the coils. This is determined by the pitch with which the springs are wound. On sectional garage door springs this is normally 15 percent. For example a 100 pound pull spring requires 15 pounds of weight to separate the coils; when a door is open the two springs will support 15 pounds of door weight without any stretch.

Most extension springs are made of oil tempered wire. These are normally coated or painted. Some springs are made of galvanized wire.

3.able break device:

cable break device ,door hardware

adjustable bottom bracket .

the raw material hot plate

zinc plated

safety device

adjustable bottom bracket

the raw material hot plate

zinc plating

spring safety device ,2" and 3" safety device

once the cable is broken ,this devoice can keep the hurt away from the door falling

4.aluminum alloy rope pulley

Equipment: CNC stamping/punching machine, CNC bending machine, CNC cutting

machine, 5~250 tons punching machines, welding machine, polish machines...

Processed material: stainless steel: copper, carbon steel

Surface treatment: Hot galvanized, polishing

Making process:Stamping, deep drawing,bending, punching, laser cutting,threading,

welding, tapping, riveting, grinding

5.air bag system

It is a safety device. When the door is down to hit something, it will up automatically.

Operation pressure:<3mbar

Battery:CR2032*2

Battery lifetime>1 year

Emission frequency: 315MHZ

Emission power:<10mW

Receiver power source:12V

6.duplex enhanced guide wheel bracket

Determining the right type of sectional door roller for your garage door tracks can be a little confusing, especially when you do not know what you need to look for in a garage door roller. To simplify things, there are two primary things you need to be aware of. First are the actual dimensions of the roller, and second is purpose that you will be using the door for. You can read below about measuring your roller and choosing the right quality of material for your door.

Other Door Accessories,Electronic Door Accessories,Automatic Door Accessories,High Speed Door Radar Detector

Shenzhen Hongfa Automatic Door Co., Ltd. , https://www.hffastdoor.com

Posted on