Floor heating is our most common heating system. When we have a floor heating system in our home, we will inevitably need to regularly maintain the floor heating . Usually we do not have too much exposure to this knowledge. What are the contents of that floor heating service ? Let's take a look!

Floor heating, method 1 , the initial use of floor heating, temperature heating should be gradual. When used for the first time, gradually increase the temperature in the first three days of heating: the first day of water temperature is 18°C, the next day is 25°C, the third day is 30°C, and the fourth day can be raised to normal temperature, ie, water temperature 45°C, surface temperature 28 °C ~ 30 °C. Can not warm up too quickly, too fast, the floor may be cracked due to expansion.

Warm maintenance, method 2 , surface temperature can not be too high. Some consumers feel that the warmer the temperature is, the higher the temperature will affect the health and warmth of the life. It is recommended to use geothermal heating. The surface temperature should not exceed 28°C, and the temperature of the water pipes should not exceed 45°C.

Floor heating maintenance, method 3 , after the installation of the system is not enabled in the winter, if the indoor temperature is lower than 5 °C, the water in the system should be blown out by the air compressor to prevent the system from freezing; when the geothermal heating system is not enabled in winter, Pay attention to protection against freezing of water separator components or freezing of water in heating pipes.

Floor heating maintenance, method 4 , When the geothermal heating system is started in winter every year, it must be in strict accordance with the provisions of the heating program cycle gradually, not one step warming in place.

Warm maintenance, method 5 , long-term use of floor heating, to prevent the room is too dry, it is recommended to humidify. Protect the floor from cracking deformation.

Floor heating maintenance, method 6 , when the geothermal heating system is enabled in winter every year, it must be strictly in accordance with the provisions of the heating program cycle gradually, not one step warming in place.

Floor heating maintenance, method 7 , low temperature hot water floor heating system heating temperature should be used 35-50 °C, should not exceed 60 °C, heating system working pressure does not exceed 0.8MPa.

Warm maintenance, method 8 , laid on the floor under the floor heating pipe only about 3-4cm, knocking, knocking the ground is easy to damage the floor heating pipe, so laying floor heating pipes on the ground is strictly prohibited knocking, impact, etc., is strictly prohibited on the ground Wedge any sharp objects to prevent damage to the warm tube. It is forbidden to bear more than 2 tons/m2 of load on the ground.

Warm maintenance, method 9 , can be used to clean the filter on the front of the water separator before use every year to ensure the cleanliness of the water pipe and prevent the pipeline from being blocked. The specific methods are as follows: First, close the inlet and outlet valve of the connecting pipe, and then open the filter. , Remove the filter and clean it, check the filter for damage, clogging, if any damage, should be replaced with the same specifications of the filter, according to the original can be installed.

Regarding warm maintenance , I will introduce it to you in general. I hope to help you, and more information on the decoration is on this site. Please stay tuned.

Warm

Super-low Ash Coal Activated Carbon

coal-based activated carbon for water purification is widely used in the deep purification of drinking water, industrial water and wastewater. Industrial water purification and gas phase adsorption, such as power plant, petrochemical, oil refinery, food and beverage, sugar wine, medicine, electronics, fish, marine and other industries water purification treatment, can effectively absorb the water in the free, sulfur and other organic pollution special The price of the coal-activated carbon filter material, especially the precursor of the Mutant (THM), is to purify the impurity and remove the odor. can also be used for industrial exhaust purification, gas desulfurization, petroleum catalytic reforming, gas separation, pressure swing adsorption, air drying, food preservation, gas masks, media carrier recovery solvent Coal activated carbon, industrial solvent filtration, decolorization, purification and so on.

Use: Used in the purification of drinking water, deodorizing, brewing industry, decoloring of pharmaceutical and chemical products.

Spec.:

Model NO.
Moisture(%)
Strength(%)
Ash(%)
Idine value(mg/g)
Carbon tetrachloride(%)
Packing density(g/L)
pH-value
Grain diameter(mm)
DX-3060
≤3
≥95
≤5
≥1010
≥60
520±20
8-10
Φ3.0
DX-3070
≤3
≥95
≤6
≥1030
≥70
500±20
8-10
Φ3.0
DX-3080
≤3
≥93
≤8
≥1050
≥80
450±20
8-10
Φ3.0
DX-4060
≤3
≥95
≤5
≥1010
≥60
530±20
8-10
Φ4.0
DX-4070
≤3
≥95
≤6
≥1030
≥70
520±20
8-10
Φ4.0
DX-4080
≤3
≥95
≤8
≥1050
≥80
460±20
8-10
Φ4.0
DX-4090
≤3
≥93
≤9
≥1080
≥90
430±20
8-10
Φ4.0
DX-40100
≤3
≥90
≤10
≥1100
≥100
370±20
8-10
Φ4.0
8×30
≤5
≥93
≤5
≥1000
≥60
460±20
8-10
-
12×40
≤5
≥93
≤5
≥1000
≥60
450±20
8-10
-

Super-Low Ash Coal Activated Carbon

Super-Low Ash Coal Activated Carbon,Coal Agglomerated Activated Carbon,Coal-Based Granular Activated Carbon,Granular Activated Carbon

SHIZUISHAN ZhongShi activated carbon co,.ltd , https://www.zscarbonchina.com

Posted on