In many industries, backup power is often referred to as the heart of the power system. Maintenance and management departments at all levels must pay attention to the maintenance and inspection of backup power from the perspective of ensuring equipment operation quality, production safety, and property safety. A good backup power system is an important force in dealing with disasters. Natural disasters such as typhoons and earthquakes often damage power supply lines, and reconstruction of these lines often takes some time. In the face of disasters, power interruption means the interruption of information, the interruption of light, and even the termination of life. At this time, backup power sources such as power generators, UPS (uninterruptible power supply), and batteries must support the power girders of the emergency system. Generator test items: No. Test items effect 1 Electrical quality parameter detection Display all the electrical quality parameters of the generator during loading, check whether the data is normal and accurate, and meet the user requirements. 2 Dynamic parameter detection Detection of important parameters of the generator set, including steady-state voltage regulation rate, transient voltage regulation rate, steady-state frequency adjustment rate, transient frequency adjustment rate, etc., is in compliance with industry standards. 3 Load capacity Detect whether the generator set can reach the rated power, and revise its nominal value to determine whether it can meet the actual power requirements. 4 Full load test Detecting the running state of the generator set under full load, whether it can run for a long time, so as to ensure the normal operation of the long-term power-off generator set. 5 Specified power for long periods of operation The user can designate the generator set to operate at a certain power for a long time according to its actual load power. 6 Sudden increase test Simulate the real power situation, when the load is suddenly added when the generator set's ability to bear and operating conditions, can detect the generator set under long-term operation of the various voltage, current, frequency is normal. 7 Three-phase unbalanced load capacity Simulate the actual power usage of the generator set under actual power usage, and adjust the generator set when the three-phase load is unbalanced. 8 Overload capacity Check whether the generator set can be operated for a short period of time with a standard overload of 110%. 9 Automatic shutdown protection Exceeding the safety setting range of the generator set, whether the generator set can automatically stop the protection to detect whether the protection of the generator set is sound. Generator test process: Q3494873746
Elevator Rope Attachment with spring, Elevator Rope Attachment with rubber, Elevator Wedge Socket, Elevator Rope Fastening
OTIS Elevator Rope
Fastening, Thyssen Elevator Rope Fastening, KONE Elevator
Rope Fastening, GiantKONE Elevator Rope Fastening, ThyssenKrupp Elevator Rope
Fastening, Schindler Elevator Rope Fastening, XJ Schindler Elevator Rope
Fastening, Xizi OTIS Elevator Rope Fastening, Mitsubishi Elevator Rope
Fastening, Shanghai Mitsubishi Elevator Rope Fastening, Fujitec Elevator Rope
Fastening, Hitachi Elevator Rope Fastening, Toshiba Elevator Rope Fastening,
Hyundai Elevator Rope Fastening, LG Elevator Rope Fastening, Sigma Elevator Rope
Fastening, Express Elevator Rope Fastening, GUANGRI Elevator Rope Fastening,
FUJI Elevator Rope Fastening, BLT Elevator Rope Fastening, CANNY Elevator Rope
Fastening, SJEC Elevator Rope Fastening, KOYO Elevator Rope Fastening, IFE Elevator
Rope Fastening
Elevator Rope Fastening,Elevator Steel Wire Rope Fasteners,Elevator Rope Fastener, Elevator Rope Attachment, Elevator Wedge Socket
CEP Elevator Products ( China ) Co., Ltd. , https://www.zjelevatordoorsystem.com