Question 1: When the X-axis of the engraving machine walks for a certain period, the Z-axis does not lift the knife, but goes upwards but goes downwards.
Solution:
1. Check whether the Z-axis motor is running normally, the power and the driver current.
2. Check the Z-axis motor cable for poor or intermittent conditions
3. Check whether the lift distance is set.
Question 2: Prompt when opening the software: three-axis alarm, initialization error signal.
Solution:
1. Check whether the two data lines of the computer and the machine are connected;
2. Check whether the fuse of the adapter board in the control box is burned and replace the fuse;
3. Check if the power supply is normal.
Question 3: Misplaced or inaccurate dimensions during engraving.
Solution:
1. Check the path of engraving software is correct or not;
2. Check the gap size of the screw rod and whether the fastening screw of the polished rod has loosened;
3. Check the software parameter settings are correct.
Question 4: The spindle motor does not turn or reverse.
Solution:
1. Check the settings of the inverter's parameters;
2. Inverter signal line is reversed.
Question 5: There is a sickle phenomenon.
Solution:
1. Z axis motor power is not enough and the coupling is loose;
2. Z-axis driver's current is too small, or the signal line is wrong
3. The data line is not connected. .
Problem 6: Axis shutdown occurs when the software is turned on.
Solution:
1. Problems with the driver or poor contact of the computer's output signal lines;
2. Bad motor wire contact.
Question 7: The machine does not have power when it is turned on.
Solution:
1. Check the start button line is connected and the button is burned out;
2. Check AC contactor for short circuit or burnout.
Question 8: The axis only goes in one direction when the button is in motion.
Solution:
1. Check whether the data cable is normal and whether the data cable jack is plugged in.
2. Check whether the motor circuit has a false weld.
Question 9: The sending software does not open properly, and the sculptured items are deformed.

Solution:
1. Reinstall new systems and software;
2. Check whether the X, Y axis screws and screws are loose;
3. Problems with engraving path