Anti-static flooring, as the name suggests, is a kind of floor that can prevent static electricity, and has the functions of moisture-proof, anti-corrosion, fire prevention, dust discharge, and anti-static. It is generally used in places with high demand for protection against electricity, such as some mysterious departments, computer rooms, chemical laboratories, aviation industry departments and related departments that we know. Anti-static floor construction process has certain similarities with common floor installation, and must go through several necessary steps such as clean-up, pay-off, and paving. Below I will introduce in detail the anti-static floor , with Xiao Bian together to understand it. Anti-static flooring Anti-static flooring, also known as dissipative static floor, is a common type of floor in a computer room. When it is grounded or connected to any of the lower potential points, it can dissipate the charge and thus effectively prevent static electricity. Because there are many reasons for causing static electricity, it is difficult for even a professional to detect it, and sometimes it is mistaken for a software failure, causing confusion. Therefore, people install anti-static flooring to prevent static electricity. When static electricity is discharged from a human body to a computer or other device, the energy reaches a certain level, and it may give people a feeling of electric shock. Therefore, after the antistatic floor is paved, antistatic grounding must be performed first, and a protective resistor must be connected. Box, otherwise it will not reach the antistatic effect of the initial installation. Anti-static floor - construction process (1) Clean the ground Whether it is for anti-static floor or ordinary floor, clean the concrete floor is a necessary one, in addition to the existence of debris, cement debris and other debris, or check the floor is flat, with or without bumps, do a good job This one can carry out the next steps. (2) Positioning the line The number of board modules and laying methods, such as outward inwards, or from inside to outside, must also pay attention to the need to avoid sewer pipes, cables and other equipment, leaving sufficient space. Then it is to put the line, put the line is to achieve a good laying marks, the dividing line bomb on the laying plane, but also on the surrounding walls to play on the elevation line to ensure the overall flatness of the anti-static floor. (3) Installation of adjustable brackets and beams According to the laid-out plan previously laid out, place the support in a fixed position, and pay attention to whether the fixing of the support is firm and whether the screws are loose or not. Then you need to put a beam on top of the support, just like putting the table in the four corners of the table. In the process of assuming the beam, it is also necessary to pay attention to whether the connection is firm and whether the screw is tightened. It is even more important to pay attention to the height of the beams, which requires the help of the level and small lines. The process must be careful to ensure that all beams are in a plane. (4) Laying panels The first few steps are to lay the foundation of the panel. After finishing, you can begin to lay the panel. The process of laying the panel also needs to pay attention to the contour, and there should be no ups and downs. After the four sides of the antistatic board are tightly connected, you're done. (5) Anti-static grounding The last step is to ground the antistatic. It is to connect the paved floor and the already buried ground line to ensure that the contact surface is in full contact. Its technical performance should meet the design requirements and construction acceptance standards. This completes the entire process of antistatic floor construction. Antistatic Flooring - Laying Requirements (1) The laying of the floor should be carried out after the indoor civil works and renovations are completed; (2) The floor should be smooth, clean, dry, free of debris, and dust-free; (3) The cables, electrical appliances, air pipes, and air-conditioning systems placed under the floor shall be completed before the installation of the floor; (4) The base of heavy equipment shall be fixed and the equipment shall be installed on the base. The height of the base shall be the same as the height of the top surface of the floor; (5) 220V/50HZ power supply and water source are available at the construction site. (1) The underside of the raised floor and the floor surface should be clean, free of dust and relics; (2) There is no scratch on the surface of the floor, there is no coating off, there is no damage to the edge; (3) After the pavement, the whole floor should be stable and firm, and there should be no swaying sensation when the staff walks on the floor. There should be no sound; (5) The height difference between adjacent floor blocks is not more than 1mm. Anti-static floor specifications 1, all steel anti-static floor specifications 600 × 600 × 30/35mm, pavement height above 100mm can be (conventional height 150mm/200mm/250mm). Structure HPL or new PVC surface layer, steel shell structure, filled with high-strength cement, all steel galvanized stent, commonly used in equipment room, monitoring room, classrooms and so on. Antistatic floor - price Anti-static floor due to the different prices of materials are not the same, the most economical is the PVC material floor, the price is more than 150 yuan -200 yuan per piece (600 * 600 * 30mm), while the steel floor price is slightly more expensive, In 200 yuan -300 yuan (600 * 600 * 30mm), and calcium sulfate anti-static flooring prices are relatively high, mostly in the 400-500 yuan left (600 * 600 * 30mm), Xiao Bian will not be listed here Interested friends can ask professionals for details. Antistatic flooring - brand The function of the anti-static floor is to solve this problem because static electricity does not work properly due to the impact on the computer. The history of the development of anti-static flooring is relatively early, so the brand of anti-static flooring is also very large, such as Shen Fei, Xiangli, Kehua, Huili, Chuangxing, etc. The following Xiaobian gives you specific introduction to several anti-static flooring. Brand>> Anti-static flooring brand 1, Shen Fei In the 90s, Shen Fei was the first floor factory in China to have passed the ISO9001 international quality system certification. It had won the honorary title of “National Foreign Trade Famous Brand Product†and “China Famous Brand Product†and was the only one in China's access flooring industry. "Excellent product" anti-static floor. Anti-static flooring brand 2, Xiangli "Xiang Li" brand is the only well-known brand identified in the domestic overhead flooring industry. It continues to develop new products for anti-static electricity and has won many honors. In order to establish a good cooperation relationship with China, we will promote the anti-static floor to the world and promote domestic economic development. Anti-static flooring brand 3, Kehua In the early 1980s, it began to develop anti-static flooring. Over the years, it has consistently adhered to the integrity of the majority of consumers. The strict scientific management of the anti-static floor makes Kehua's anti-static floor have a very good prospect of development, and build China's famous anti-static floor brand. Anti-static flooring brand 4, Hui Li Huili is a professional floor manufacturer specializing in export-oriented products. It is a professional flooring manufacturer that integrates design, manufacture, sales and installation. They have won the customers' favor with the prestige of "customer first, good quality" and become One of our famous anti-static floor brands. Anti-static flooring brand 5, a star Established in the early 1990s, it is the only company in China's domestic industry that designs, develops and manufactures all product molds and fixtures, and manufactures molds for its peers. In order to meet the ever-increasing demands of customers, they have begun to design and manufacture their own anti-static flooring, which has become one of the top ten antistatic floor brands in China. Editor's summary: The above is the introduction of anti-static floor construction technology and anti-static floor specifications brought by Xiaobian. We hope this article helps you. For more decoration knowledge, please pay attention to this website information channel. Flooring Flooring Selection Flooring Brand Brass Deep Drawing Parts,Wear Bowl Liner,Deep Drawing Bogie,Center Wear Bowl Liner JIANGSU TONGDE INTERNATIONAL TRADE CO.LTD. , https://www.tongdetrades.com
Antistatic flooring - acceptance criteria
(4) The edge of the floor shall ensure a straight line, and the dislocation of the adjacent floor shall not exceed 1mm;
2, aluminum alloy anti-static floor specifications 600 × 600 × 35/40mm, paving height of 80mm or more can be (conventional height 150mm/200mm/250mm). High wear-resistance HPL or universal PVC surface layer, all aluminum base, steel galvanized bracket, generally used in various electronic workshops, such as clean workshops, electromagnetic shielding rooms, microelectronics workshops, for the high cleanliness requirements of the computer room All-body PVC surface.
3, imitation of imports of anti-static floor specifications 600 × 600 × 40mm, paving height of 80mm or more can be (conventional height 150mm/200mm/250mm).