Brass fasteners are used for their physical and aesthetic properties. Brass is utilized due to its high thermal conductivity and corrosion resistant properties, it is suitable for use in hot and cold environments, and resistant to water corrosion, making it a staple of industries such as heating and plumbing. Brass fasteners are largely non-magnetic (like any fastener, slight magnetic properties can develop during the manufacturing process) and resistant to tarnishing. Brass Nut,Adjustable Brass Nut,Brass Strat Nut,Brass Cap Nut Taizhou Hongchuang Hardware Co., Ltd. , https://www.taizhouhongchuang.com
Brass fasteners are suited for some marine environments, including brackish water and slow current sea water; brass in this environment develops a protective green coating. Brass fasteners are also commonly used with wood applications, as the golden coloring blends well with the tan wood. Brass is a softer metal and must be used with care, always drilling pilot holes and using driver bits that fit the head of the screw precisely to prevent stripping. Brass Bolts also require a pilot hole be driven before installtion.
Electric diaphragm pumps occupy a very important position in the development of national economy in our country. They have irreplaceable status in other fields such as petrochemical, ceramics, metallurgy, construction, environmental protection, sewerage and chemical industry. Although the electric diaphragm pump in the work and other pump equipment will have the same failure, but this does not affect the use of such products. Next will introduce several common electric diaphragm pump fault and troubleshooting. Electric diaphragm pump failure analysis and solution 1, the diaphragm pump air valve icing fault solution: Check the compressed air moisture content is too high, the installation of air drying equipment 2, the diaphragm pump outlet bubbles have a problem Solution: Check the diaphragm Whether it is broken, check whether the locking clamp, especially the inlet pipe clamp. 3, the product flows out of the air outlet failure solution: check the diaphragm is broken, check the diaphragm and the clamp on the shaft is clamping 4, pneumatic, electric diaphragm pump is not moving or operating very slow Troubleshooting: Check the air inlet End of the filter or air filter device for impurities; check the air valve is stuck, with a cleaning fluid cleaning air valve. 5, pneumatic diaphragm pump work, but the flow is small or no liquid out of the solution to solve the problem: Check the pump cavitation, reducing the speed of the pump to allow liquid into the liquid chamber; Check the valve ball is stuck. If the operating fluid is incompatible with the pump elastomer, the elastomer will swell. Please replace the appropriate material elastomer. Electric diaphragm pump during use, although there will be a breakdown of the situation, but as long as the workers based on the actual situation to make a reasonable treatment, I believe these failures will not have a great impact on the work. It is impossible to guarantee that the equipment will not cause any accidents at work in time if there is more experienced workers. We can only minimize the occurrence of such accidents. In order to better use of equipment and protection of production.